Command
|
Default |
| Phone Number 1 (Primary) |
11 followed by 10 digit phone number |
none |
| Phone Number 2 |
12 followed by 10 digit phone number |
none |
| Phone Number 3 |
13 followed by 10 digit phone number |
none |
Examples:
115080000000 - Enter the primary cell-phone
# 508-000-0000.
126171112222 - Enter the secondary cell-phone # 617-111-2222.
11 - Erase Phone Number 1
Easy Commands (case insensitive)
| Command Description |
Command |
| Alarms Off (All Off) |
Off |
| Alarms On (All On) |
On (default) |
| Send status text to phone #1 |
Status |
| Send status to email #1 |
Estatus |
| Send diagnostic information to phone#1 |
Diag |
| Send list of phone #’s & email addr stored to phone#1 |
List |
| Send alarm settings |
Setting |
| Switch ON |
Swon |
| Switch OFF |
Swoff (default) |
Example:
Status – Request a status text message to be sent to the Primary cell-phone#.
Status5080000000 – Request a status text message to be sent to 508-000-0000.
Any 10-digit phone number can be appended to the following commands and the response text message will be sent to that number:
Status, Diag, List, Setting, Info
Append an email address after the Estatus command and a status email will be sent to the address specified
BOAT ALARM SYSTEM Advanced Command List
EMAIL Message Alarm Alerting Addresses
| |
Command
|
Default
|
| Email Address 1 |
21 followed by an email address |
None |
| Email Address 2 |
22 followed by an email address |
None |
| Email Address 3 |
23 followed by an email address |
None |
Example: 21joe@email.com - Enter the primary email address
joe@email.com
Message Alarm Alerting Enable or Disable
Command Description |
Function |
Numeric Command |
Default |
Remote Sensor not responding |
On=1 Off=0 |
80 followed by 0 or 1 |
1 |
Water Level |
On=1 Off=0 |
81 followed by 0 or 1 |
1 |
Motion |
On=1 Off=0 |
82 followed by 0 or 1 |
1 |
Microphone Alarm |
On=1 Off=0 |
83 followed by 0 or 1 |
1 |
Base Unit DC/AC Power |
On=1 Off=0 |
84 followed by 0 or 1 |
1 |
Base Unit Battery |
On=1 Off=0 |
85 followed by 0 or 1 |
1 |
Base Unit Temperature |
On=1 Off=0 |
86 followed by 0 or 1 |
1 |
Remote Unit Battery |
On=1 Off=0 |
87 followed by 0 or 1 |
1 |
Remote Unit Temperature |
On=1 Off=0 |
88 followed by 0 or 1 |
1 |
Example: 820 – Disable Motion Sensor alarm messages.
General System Commands
Command Description |
|
Numeric Command |
Default |
Set System Name |
|
90 followed by name
(15 characters or less) |
BoatNanny |
Set to Factory Defaults |
|
91 |
|
Relay Switch Mode |
0=Motion Siren
1=Normal |
94 followed by 0 or 1 |
1 |
Example : 90MyBoat1 – Change system name to MyBoat1.
94 command – When “0”, the Switch is closed when the Motion Alarm is activated, then opens after 2 minutes. The motion activated switch will be re-armed after one hour. The “SWON” and “SWOFF” commands override the switch position.
Other” System Commands
Command Description |
Range |
Numeric Command |
Default |
Alarm Base Temp Hi |
0 to 185 (in F) |
70 followed by Temp |
120 |
Alarm Base Temp Lo |
0 to 185 (in F) |
71 followed by Temp |
40 |
Alarm Remote Temp Hi |
0 to 185 (in F) |
72 followed by Temp |
140 |
Alarm Remote Temp Lo |
0 to 185 (in F) |
73 followed by Temp |
40 |
Set Motion Sensitivity |
1 to 10 |
74 followed by sensitivity |
7 |
Set Audio Alarm Sensitivity |
1 to 10 |
75 followed by sensitivity |
8 |
Example :
72150 - Set Remote High Temperature Alarm to 150F.
Sensitivity 1 is the least sensitive setting, 10 is the most sensitive setting.
•A Command message consists of a 2-digit command (letters for Easy Commands), followed by an optional data field.
• Commands are sent to the BoatNanny via SMS text message
from a cell phone or web sites that allow text messages to be sent
(www.cingular.com for example).
•Motion Sensor will activate 60 seconds after the unit is switched on
•A daily status message is sent at noon.
•When there is an alarm condition, an alarm message is sent to all stored phone numbers and email addresses at once. When the condition returns to a normal state, another message is sent. In case of a temperature alarm, the temperature must return inside 5F of the thresholds before a "Normal State" message is sent.
• In case of the ‘Motion’ alarm and ‘Remote Sensor not responding’ alarm, a message is sent out only once. These alarms are re-armed after 1hr to avoid multiple alarm messages